Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1 Year Quality Guarantee |
Still deciding? Get samples of US$ 315/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Main Features:
Suitable for Ration Batching Scale with 14-Material&2-Speed Feeding or 16-Material&1-Speed Feeding [Single-scale Mode].
² EMC design with high anti-jamming capability, suitable for industrial environment.
² Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.
² 7"/10.2" Ultralight and ultrathin TFT touch screen with embedded weighing/control module.
² Loadcell Interface
Max. Connection Quantity: 16 Loadcells (350Ω).
24-bit High-precision and high-speed ∑-A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 800Hz.
Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
² I/O Interface
9 Definable normally open switch inputs [DI] and 18 definable normally open transistor switch outputs [DO].
Optional 'High/Low Speed Feed' DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.
2 Definable analog signal AO[0~10V] for weight signal output or 'High/Low Speed Feed' control.
² Digital Communication Interface
COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.
COM[RS232] for connecting RS232 Serial Printer.
USB1 for connecting USB mouse, downloading HMI software from U-disk and copying data to U-disk.
² Software Function
Manual Screen-locking/Screen-unlocking, Auto Screen-locking, Digital Setting&Calibration and I/O Testing functions available.
Initial Zero Adjustment after Power-on, Auto Zero Tracking, Zero Fine Adjustment and Zero Calibration functions available.
Load Calibration and Loss Calibration functions available.
10 Recipes for batching control.
Optional 'Fall Value Auto Correction' function.
Optional 'Auto Pause for Deviation Alarm', 'Auto Pause while Gross Weight Upper Limit Alarming', 'Manual Pause' and 'Auto Re-feed' functions.
Optional 'Target Batch Control' function [With Target Batch Count finished, the batching process will stop automatically].
The Batch Records can be printed automatically.
Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.
Name |
Operation |
Note |
[Login] |
User Login. Exfactory Passwords: ² Operator: None. ² Engineer: 0. ² Administrator: 1. |
Operation 'Main Menu / F5 User / Password / PSW Set' for Modifying Password. |
[User Name] |
After password inputted, the matching User Name will be displayed. |
² Operator: User with lowest authorization. ² Engineer: User with higher authorization. ² Administrator: User with highest authorization. |
[Operate] |
Enter 'Main Operation Interface'. |
Operation 'Main Menu / F5 User / Password / Login [Logoff]' for Re-login and Logoff. |
Button Operation
Name |
Operation |
State Indicator |
Authorization |
[Auto] |
Auto / Manual [Emergency Stop] switch. |
Green: Auto state. Grey: Manual state. |
All Users |
[Start] |
Start. |
Green: Running state. Grey: Stop state. |
|
[Re-run] |
Clear Alarm & Recover Running. |
|
|
[Last] |
Last Batch [Normal Stop]. Stop after the present batch finished. |
Flashing Red. |
|
[Pause] |
Pause. |
|
|
[E-stop] |
Emergency Stop. |
|
|
[Alarm] |
Alarm Query / Clear Alarm. 'Auto/Pause' state: Recover Running after clearing alarm. |
Red: Alarm state. |
|
[Mat.] |
Material Selection for Auto-Batching. Mixer in Weighing Hopper Running Selection While High-speed Feeding. |
Green/Blue: Selected. Grey: Unselected. |
|
[Print] |
Report Print: ² [ Auto Print]: Print Batch Records. ² [Total]: Print Totalizing Report. ² [Recipe]: Print Working Recipe. |
|
|
[Lock] |
Screen-locking: Locking/unlocking the operating buttons of main display interface. Auto Screen-locking: Refer to parameter [901]. |
Flashing Red: Locked. Grey: Unlocked. |
|
[Menu] |
Enter Main Menu. |
|
|
[User] |
User Login. Display: Operator / Engineer / Admin. |
|
|
[Zero] |
Zero Fine Adjustment [No Power-down Protection]. |
Flashing green. |
|
[High] |
Manual Start/Stop Mn High-speed Feeding. |
Green: Working state. |
|
[Low] |
Manual Start/Stop Mn Low-speed Feeding. |
Green: Working state. |
|
[Dump] |
Manual Start/Stop Dumping. |
Green: Working state. |
|
[Mn] |
Material Selection for Manual Operation. |
|
|
[Clear] |
Clear Screen: Clear the display values of Feeding Weight, Totalized Weight and Batch Count'. |
|
Engineer Administrator |