Basic Info.:
Model NO.
|
BST106-K01B[BH] |
Accuracy |
0.01g
|
Display Type
|
Touch Screen
|
Display Digits
|
Touch Panel
|
Measure Method
|
Automatic |
Shell Material
|
Stainless Steel |
Application |
Heavy Industrial
|
Certification | CE |
Customized
|
Non-Customized
|
Power Supmeter
|
DC24V |
Max Connection
|
16loadcell | Di | 9 |
Do | 18 | Ao | 2 |
COM&COM1
|
RS232 | COM2 | RS485 |
Verification Accuracy
|
0.02%
|
Batching Accuracy
|
0.2%-0.5%
|
Transport Package
|
Carton | Specification |
7" or 10"
|
Trademark
|
Supmeter | Origin | China |
HS Code
|
8537109090 |
Production Capacity
|
5000/Month |
Product Description:
² Suitable for Ration Packing Scale with optional Hopper-weighing Mode, Bag-weighing Mode and Loss-in-weight Mode.
² EMC design with high anti-jamming capability, suitable for industrial environment.
² Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.
² 7"/10.2" Ultralight and ultrathin TFT touch screen with embedded weighing/control module.
² Loadcell Interface
l Max. Connection Quantity: 16 Loadcells (350Ω).
l 24-bit High-precision and high-speed ∑-A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 800Hz.
l Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
² I/O Interface
l 9 Definable normally open switch inputs [DI] and 18 definable normally open transistor switch outputs [DO].
l Optional 'High/Medium/Low Speed Feed' DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.
l 2 Definable analog signal AOs[0~10V] for weight signal output or 'High/Medium/Low Speed Feed' control.
² Digital Communication Interface
l COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.
l COM[RS232] for connecting RS232 Serial Printer.
l USB1 for connecting USB mouse, downloading HMI software from U-disk and copying data to U-disk.
² Software Function
l Manual Screen-locking/Screen-unlocking, Auto Screen-locking, Digital Setting&Calibration and I/O Testing functions available.
l Initial Zero Adjustment after Power-on, Auto Zero Tracking, Zero Fine Adjustment and Zero Calibration functions available.
l Load Calibration and Loss Calibration functions available.
l 10 Recipes for packing control.
l Optional 'Fall Value Auto Correction' function.
l Optional 'Auto Pause for Deviation Alarm' and 'Auto Re-feed' functions.
l Optional 'Target Batch Control' function [With Target Batch Count or Target Batch Weight finished, the packing process will stop automatically].
l The Batch Records can be printed automatically.
l Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
Main Menu | Second Menu | Description | Authorization |
F1 Settings | Scale | Scale parameters setting. | Engineer |
Calibration | Calibration parameters setting. | ||
Setpoint | Setpoint parameters setting. | ||
Mode | Working mode parameters setting. | ||
Timer | Timer parameters setting. | ||
Comm. | Communication parameters setting. | ||
Display | Main user interface parameters setting. | ||
F2 Calibration | 1 Static Cal. | Zero Calibration without loading on the scale to correct Zero Value. | Technician |
Load Calibration with loading standard weights on the scale to correct Span Coefficient. | |||
2 Loss Cal. | Loss Calibration to correct Span Coefficient according to the weight of the materials dumped from the weighing bucket. | ||
F3 Statistics | Real-time | Real-time Data Query. | |
Batch Rec. | Historical Batch Records Query / USB Copy [Excel Format] / Delete. | ||
Hour Rec. | Hour Records Query / USB Copy [Excel Format] / Delete. | ||
Run Time | Bulk/Medium/Dribble Feeding Time of the Last Batch. | ||
Alarm Query | Alarm Query / Clear Alarm. | ||
F4 Recipe | Recipe management. | Engineer | |
F5 User | Password | Login/Password Set/Logoff. Exfactory Passwords: Operator: None; Technician: -1. Engineer: 0; Administrator: 1. |
Technician |
Fac. Code | Factory Code. | Factory | |
Fac. Inf. | Factory Information. | ||
F6 Timer | Date&time Setting. | Engineer | |
F7 Default | Part-Default | Reset partial parameters to default values. | Administrator |
All-Default | Reset all parameters to default values. | ||
Para. Backup | Parameter Backup. | ||
Para. Recover | Parameter Recover. | ||
F8 I/O Test | Reliability | I/O Reliability Test. | |
AO Adjust | AO Zero/Full Adjustment and AO Linearity Test. | ||
F9 I/O Assignment | DO Assign | DO Function Assignment. | |
DI Assign | DI Function Assignment. | ||
AO Assign | AO Function Assignment. | ||
Operate | Return to main user interface. | Technician |
Panel-mounting Operation Interface: